| Core Components | Model | Cooling Medium | Working Temperature | Cooling Capacity |
|---|---|---|---|---|
| PLC | DYF200t-800t | Antifreeze, Freon | -25°C - 45°C | 200t - 1200t |
| Customized Text and Image Logo | Customization | Power Rating | Brand | Voltage |
| Spraying Process | Non-standard Customization | ≦3500W | DYF | 220v - 380v |
The ICS Series Integrated Cooling Station serves as a professional cooling unit designed for flexibility. Depending on the specific cooling load requirements of the user side, it can operate as a standalone unit or be deployed in multi-unit parallel configurations for combined cooling.
This series is widely utilized across a diverse range of industries, including Data Centers, Semiconductor, PV Modules, Battery Manufacturing, and Pharmaceuticals.
The IDC Series Intelligent Data Center is part of the factory-precast container product line. Using prefabricated containers as its foundation, it integrates power systems, IT cabinets, fire protection systems, environmental monitoring systems, intelligent security systems, HVAC systems, lighting systems, and interior decoration systems into a highly modular outdoor data center solution.
The IDC series intelligent data centers can replace indoor data centers and are widely used in industries such as telecommunications, IT, finance, and public utilities.
Cleanroom Laboratory Project: A Class 100,000 cleanroom refers to a controlled environment where the number of dust particles with a diameter ≥0.5μm per cubic meter of air is ≤3,520,000, and microbial limits comply with relevant industry standards. It is widely used in industries such as electronics, food, pharmaceuticals, and medical devices. Construction must strictly adhere to the Cleanroom Construction and Acceptance Code (GB 50591-2010), following the principles of "concealment before finishing," "civil construction before purification," and "rough finishing before fine finishing," with phased and orderly implementation.
We specialize in the installation of dedicated air conditioning systems and supporting interior fit-outs for modular data centers, committed to delivering a comprehensive solution ranging from hot/cold aisle containment to full facility finishing. By optimizing airflow organization to lower PUE and integrating concealed piping layouts, we build a modern, energy-efficient, and aesthetically pleasing data fortress that is designed for ease of maintenance.
The ICS Series is designed for wide utilization across modern industries, including Data Centers, Semiconductor manufacturing, PV Modules, Battery Manufacturing, and Pharmaceuticals.
Yes. Depending on the cooling load demands of the user side, the cooling station can function either as a standalone unit or be deployed in multi-unit parallel configurations for combined cooling.
The modular data center integrates power systems, IT cabinets, fire protection, environmental monitoring, security, HVAC, lighting, and internal decoration into a precast container containerized structure.
A Class 100,000 cleanroom restricts the concentration of dust particles (diameter ≥0.5μm) to ≤3,520,000 per cubic meter of air, with microbial levels designed to meet stringent industry-specific standardization codes.
Our solutions optimize airflow organization to lower the Power Usage Effectiveness (PUE), integrate dedicated air conditioning systems, and implement concealed piping layouts to maximize heat exchange efficiency.